Fluke 1550C 5 kV Insulation Tester
Perhatian!
Spesifikasi Fluke 1550C 5 kV Insulation Tester
- Test voltages to up 5 kV and save time by trending on the spot only with Fluke Connect™
- CAT III 1000 V, CAT IV 600 V safety rating
- Warning function alerts the user that line voltage is present and gives the voltage reading up to 600 V AC or DC for increased user safety
- Selectable test voltages in 50 V steps from 250 V to 1000 V, and 100 V steps above 1000 V
- Measurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recall
- Long battery life gives the user over 750 tests between charges
- Automatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup
- Guard system eliminates the effect of surface leakage current on high-resistance measurements
- Large digital/analog LCD for easy viewing
- Capacitance and leakage current measurement
- Ramp function for breakdown testing
- Resistance measurements up to 2 TΩ
- Timer settings up to 99 minutes for timed tests
- 3-year warranty
| Electrical Specifications | ||
| The tester's accuracy is specified for one year after calibration at operating temperatures of 0°C to 35°C. For operating temperatures outside the range (-20°C to 0°C and 35°C to 50°C), add ± .25% per °C, except on the 20% bands add ± 1% per °C. | ||
| Insulation Resistance Measurement | ||
| Test voltage (DC) | ||
| 250 V | Range | < 250 kΩ, 250 kΩ to 5 GΩ 5 GΩ to 50 GΩ > 50 GΩ |
| Accuracy (± reading) | Unspecified 5% 20% Unspecified |
|
| 500 V | Range | < 500 kΩ 500 kΩ to 10 GΩ 10 GΩ to 100 GΩ > 100 GΩ |
| Accuracy (± reading) | Unspecified 5% 20% Unspecified |
|
| 1000 V | Range | < 1 MΩ 1 MΩ to 20 GΩ 20 GΩ to 200 GΩ > 200 GΩ |
| Accuracy (± reading) | Unspecified 5% 20% Unspecified |
|
| 2500 V | Range | < 2.5 MΩ 2.5 MΩ to 50 GΩ 50 GΩ to 500 GΩ > 500 GΩ |
| Accuracy (± reading) | Unspecified 5% 20% Unspecified |
|
| 5000 V | Range | < 5 MΩ 5 MΩ to 100 GΩ 100 GΩ to 1 TΩ > 1 TΩ |
| Accuracy (± reading) | Unspecified 5% 20% Unspecified |
|
| Bar graph range | 0 to 1 TΩ (1550C) - 0 to 2 TΩ (1555) | |
| Insulation test voltage accuracy | -0%, +10% at 1 mA load current | |
| Induced AC mains current rejection | 2 mA maximum | |
| Charging rate for capacitive load | 5 seconds per μF | |
| Discharge rate for capacitive load | 1.5 s/μF | |
| Leakage current measurement | Range | 1 nA to 2 mA |
| Accuracy | ± (5% + 2 nA) | |
| Capacitance measurement | Range | 0.01 μF to 15.00 μF |
| Accuracy | ± (15% rdg + 0.03 μF) | |
| Timer | Range | 0 to 99 minutes |
| Resolution setting | 1 minute | |
| Resolution indication | 1 second | |
| Live circuit warning | Warning range | 30 V to 660 V AC/DC, 50/60 Hz |
| Voltage accuracy | ± (15% + 2 V) | |
| Software specifications | FlukeView Forms™ basic software requires a PC running Windows XP, Windows Vista , Windows 7 or Windows 8. | |
| General Specifications | ||
| Display | 75 x 105 mm | |
| Power | 12 V lead-acid rechargeable battery, Yuasa NP2.8-12 | |
| Charger Input (AC) | 85 V to 250 V AC 50/60 Hz 20 VA | |
| This Class II (double insulated) instrument is supplied with a Class 1 (grounded) power cord. The protective earth terminal (ground pin) is not connected internally. The extra pin is for added plug retention only. | ||
| Dimensions | 269 x 277 x 160 mm (10.6 x 10.9 x 6.3 in) | |
| Weight | 3.7 kg (8.2 lb) | |
| Temperature (operating) | -20°C to 50°C (-4°F to 122°F) | |
| Temperature (storage) | -20°C to 65°C (-4°F to 149°F) | |
| Humidity | 80% to 31°C decreasing linearly to 50% at 50°C | |
| Altitude | 2000 m | |
| Enclosure sealing | IP40 | |
| Input overload protection | 1000 V AC | |
| Electromagnetic compatibility | EN 61326 | |
| Safety compliance | IEC 61010-1: Overvoltage category II, Pollution Degree 2. IEC 61010-2-030: Measurement 600V CAT IV / 1000V CAT III IEC 61557-1, IEC 61557-2 |
|
Andalan Prima
CV. ANDALAN PRIMA SEJAHTERA
Supplier Laboratory Equipment, Glasware, Chemical, Electrical Test & Measuring Instrument
Jakarta
JL. SUMUR BATU RAYA No.1
skype : vitha.andalan2
Bekasi :
Muhtar tabrani Blok A-7 No 16
Telpon: 021-29253184,29253187,46560833, 46560834,
Mobile : 081280842187
Telp : +62-21-29253184, 29253187
Telp : +62-21-29253186
email : andalan1974@yahoo.com
skype : vitha.andalan2
MEDAN :
JL JAMIN GINTING NO 6 MEDAN
p : 061-8365706, 77804098
fax : 061-8365706
email : andalprima@ yahoo.co.id
AGENT FROM :
1. - JENCO INSTRUMENTS ( USA)
CONDUCTIVITY : POCKET - PORTABLE & BENCH tOP
DO METER : PORTABLE & BENCH TOP
PH METER : POCKET , TESTER , PORTABLE ( ANALOG / DIGITAL) & BENCHTOP ( ANALOG / DIGITAL) , INLINE - STATION
ION METER : POCKET , TESTER , PORTABLE & BENCHTOP, INLINE
2. - JEKEN ULTRASONIC CLEANER ( CHINA)
- Mekanical Mechanical control Timer
- Digital control Timer Heating Temperature control function
3.- MITECH INSTRUMENTS
- Ultrasonic Flow detector
- Coating thickness Meter
- Hardness Tester
Produk / Jasa Utama
Menjual:- HACH, MEMMERT, KYORITSU, INSTEK, MERCK, JENCO, BUCK SCIENTIFIC, ADWA, PYREX-IWAKI, PYREX USA, BRAND, WHATMAN, Aquadiagnostic, CARBOLITE, JENWAY, LOVIBON, SPECTRONIC, DAVIS WEATHER STATION, METONE, SHINAGAWA(DRY/ WET GAS METER
Disributor for Laboratory equipment, reagent, glassware, Test & Measuring Instrument.
Supplier and stockist for Laboratory Instrument and Equipment. - combustion Gas Analyzer
- Smokemeter
Produk Lainnya
ANCEL AS300 Automotive Basic OBD2 Sc
Rp. 383.000
S2S Drone kamera jarak jauh fotograf
Rp. 103.000
Lensa Kamera Hp Apexel 28x Zoom Padu
Rp. 97.000
Lenovo IdeaPad Slim 3i 14IRU8 Intel
Rp. 7.099.000
Tripod Proyektor Stand Bracket Proje
Rp. 45.000