KOEHLER K16500 Rapid Flash Closed-Cup Tester

Update Terakhir
27-05-2016
Dilihat Sebanyak
73 kali
Lokasi
Jawa Barat - Bekasi - Bekasi Utara
Harga
Kontak Kami
Bagikan
+ Penawaran

Perhatian!

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi lebih aman.

Spesifikasi KOEHLER K16500 Rapid Flash Closed-Cup Tester

 Test Method
Verifies the flash point or the sustained burning qualities of small samples in the range of –30°C to +300°C.

Features and Benefits
• Conforms to ASTM D3278, D3828, D4206; DOT CFR 49-173.115; IATA;ISO 9038 and related specifications

• One minute test with a 2mL sample

• Simple to operate

K16500 Rapid Flash Tester
Rapid Tester® provides rapid determinations of flash point or sustained burning qualities by using a small sample. A flash/no flash test result is achieved in one minute for flash points below 212°F (100°C) with a 2mL sample. Ideally suited for quality assurance and environmental compliance testing as well as actual flashpoint for paints, fragrances, hydrocarbons and other liquids. Open cup models are used for determining sustained burning qualities characteristics of mixtures of flammable and nonflammable liquids or liquids with widely different flash points when assessing flammability characteristics. Features convenient semi-automatic operation for flash/no flash tests. Set the test temperature on the digital display and inject a 2mL or 4mL sample into the sample cup. The tester quickly stabilizes itself at the desired value, permitting the test flame to be applied and the result to be observed by the operator. Unit also performs conventional determinations of actual flash temperature by the small scale closed tester method.

Two models are offered: the Closed Cup Model is for routine flash point tests in the range from –30 to +300°C (–22 to +572°F); the Open-Cup Model is for sustained burning tests in the range from ambient to 212°F (100°C). Both models include automatic temperature control with °C/°F selector switch, syringe, electronic timer, integral NIST traceable thermometer, and an external hose adapter valve for connection to a customer-supplied fuel cylinder or other fuel source.

Specifications
Conforms to the specifications of:
ASTM D3278, D3828, D4206; IP 303; ISO 3679, ISO 3680, ISO 9038;
DOT CFR 49-173.115; IATA

Included Accessories
Thermometer, range 32 to 572°F (0 to 300°C)
Syringe

Dimensions lxwxh,in.(cm)
15x23.4x6.3 (38.1x8.6x16.2)
Net Weight: 10 lbs (4.6kg)

Shipping Information
Shipping Weight: 16 lbs (7.26kg)
Dimensions: 2.3 Cu. ft.

Ordering Information
 
Catalog
Number
Product Description
Electrical Requirements
K16500
Rapid Flash Tester, Closed Cup
Aluminum Test Cup/Brass Lid & Shutter
115V
K16591 Rapid Flash Tester, Closed Cup
Aluminum Test Cup/Brass Lid & Shutter
220-240V
K16502 Rapid Flash Tester, Closed Cup
Stainless Steel Test Cup/Lid & Shutter
115V
K16592 Rapid Flash Tester, Closed Cup
Stainless Steel Test Cup/Lid & Shutter
220-240V
K16503 Rapid Flash Tester, Open-Cup
Aluminum Test Cup
115V
K16593 Rapid Flash Tester, Open-Cup
Aluminum Test Cup
220-240V
K16504 Rapid Flash Tester, Open-Cup
Stainless Steel Test Cup
115V
K16594 Rapid Flash Tester, Open-Cup
Stainless Steel Test Cup
220-240V

Accessories
 
Catalog
Number
Product Description
Temperature Range
K16506
Fuel Cylinder Valve  
K16507
Heat Transfer Compound for thermometer  
K16508 Metal Cooling Block to facilitate cooling of the sample cup between tests  
K16509 Refrigerant Charged Cooling block to hold cooling mixture for subambient testing  
K16510 Syringe 2mL/4mL  
K16511 Thermometer
32 to 572°F/0 to 300°C
K16512 Thermometer
32 to 230°F
K16513 Thermometer
212 to 572°F
K16514 Thermometer
0 to 110°C
K16515 Thermometer
100 to 300°C
K16516 Thermometer
-36 to +105°F
K16517 Thermometer
-38 to +40°C
Tampilkan Lebih Banyak

Andalan Prima

 Penjelasan Ringkas

 CV. ANDALAN PRIMA SEJAHTERA
Supplier Laboratory Equipment, Glasware, Chemical, Electrical Test & Measuring Instrument

Jakarta
JL. SUMUR BATU RAYA No.1
skype : vitha.andalan2
Bekasi : 
Muhtar tabrani Blok A-7 No 16
Telpon: 021-29253184,29253187,46560833, 46560834, 
Mobile :  081280842187 
Telp     :  +62-21-29253184, 29253187
Telp     :  +62-21-29253186
email :  andalan1974@yahoo.com
skype : vitha.andalan2

MEDAN : 
JL JAMIN GINTING NO 6 MEDAN
p : 061-8365706, 77804098
fax : 061-8365706
email : andalprima@ yahoo.co.id

AGENT FROM : 
1. - JENCO INSTRUMENTS ( USA) 

CONDUCTIVITY : POCKET - PORTABLE & BENCH tOP
DO METER : PORTABLE & BENCH TOP
PH METER : POCKET , TESTER , PORTABLE ( ANALOG / DIGITAL) & BENCHTOP ( ANALOG / DIGITAL) , INLINE - STATION
ION METER : POCKET , TESTER , PORTABLE & BENCHTOP, INLINE

2. - JEKEN ULTRASONIC CLEANER ( CHINA) 

- Mekanical Mechanical control Timer
- Digital control Timer Heating Temperature control function

3.- MITECH INSTRUMENTS

- Ultrasonic Flow detector
- Coating thickness Meter
- Hardness Tester

Produk / Jasa Utama

Menjual:
  • HACH, MEMMERT, KYORITSU, INSTEK, MERCK, JENCO, BUCK SCIENTIFIC, ADWA, PYREX-IWAKI, PYREX USA, BRAND, WHATMAN, Aquadiagnostic, CARBOLITE, JENWAY, LOVIBON, SPECTRONIC, DAVIS WEATHER STATION, METONE, SHINAGAWA(DRY/ WET GAS METER


    Disributor for Laboratory equipment, reagent, glassware, Test & Measuring Instrument.

    Supplier and stockist for Laboratory Instrument and Equipment.
  • combustion Gas Analyzer
  • Smokemeter
Tampilkan Lebih Banyak

Andalan Prima

Free Member
 
Jl. Muchtar Tabrani Bintang Metropole Blok A7 No16
Jawa Barat - Bekasi
Login Terakhir 21-03-2019
02129253187
081280842187

Produk Lainnya


CALL
Alat Uji Lingkungan
CALL
Alat Uji Lingkungan
CALL
Alat Uji Lingkungan
CALL
Alat Uji Lingkungan
CALL
Alat Uji Lingkungan
CALL
Alat Uji Lingkungan