Spesifikasi WILKS OIL IN WATER/SOIL TESTING PORTABLE, RUGGED INFRARED ANALYZER

 

OIL IN WATER/SOIL TESTING
PORTABLE, RUGGED INFRARED ANALYZER


The InfraCal 2 TRANS-SP is recommended for measuring oil in water, TPH in soil or FOG in wastewater using the traditional EPA methods 413.2 and 418.1 or ASTM method D7066-04.  With over 3,500 oil and grease monitors in worldwide use today, InfraCal 2 analyzers, originally developed by Wilks, have become a standard for the petrochemical industry. These essential tools ensure that oil content levels are below the regulated limit in water, drill cuttings, and soil. The InfraCal 2 provides real-time results for all operators needing to monitor oil in water.

Produced water in offshore oil wells presents particular challenges to wastewater treatment systems. In order to ensure oil levels in the water are under the regulatory limit before discharge, it is important to do regular testing. Infrared is a widely accepted oil content measurement and the Wilks Infrared technology has been considered an industry standard for this application for over 20 years.

The InfraCal2 Analyzer gives results in less than 15 minutes and has a reputation for the rugged durability required in the off-shore environment. The sampling requires a few simple steps that can be performed by non-technical personnel. The water is mixed with the extraction solvent, shaken, and then presented to the InfraCal 2 Analyzer for measurement. Since the extract is deposited into a 10 mm quartz cuvette cell with Teflon stopper the light end volatile components are retained for measurement.

The InfraCal 2 has added features such as touch screen display, data storage and transfer, a multi-language interface and password protected settings.  The internal battery pack allows for portability and up to 12 hours continuous use.

  • Minimum Detection Limit Water: 0.1 ppm
  • Minimum Detection Limit Soil: 1 ppm
  • Solvent(s): Perchloroethylene, S-316, Freon-113
  • Method Complies: ASTM D7066, EPA 413.2 & 418.1
  • Method Compares: EPA 1664 & ISO 9377-2

Features & Benefits

  Benefits

  Features

Sub-ppm Detection

Reads down to 0.1ppm (+/-0.1ppm) for analysis that requires sub-ppm level of oil in water

Internal Data Storage 

Data storage including each measurement tagged with analyst, location and date/time information, and password protected instrument settings

Export

Directly to your PC via USB or a Flash Drive

Touch Screen Display

The touch screen display allows a simple set up for quick operation along with an easy calibration wizard.

Internal Battery

The internal battery pack allows for portability and up to 12 hours continuous use.
Multi-Language Interface

English, Spanish, French, Arabic

Password Protected Settings

Calibration and data are password protected to avoid accidental deletion

Multiple Calibrations

A multitude of calibrations can be stored allowing the InfraCal to be moved to different locations without the need to recalibrate after initial calibration at a particular location

No need for Installation/Commissioning

The InfraCal 2 is a portable analyzer, weighing less than 5 lbs. with a 6 in. square foot print, requiring no installation or commissioning, little to no routine maintenance or recalibration.

Minimal Consumables

The analysis requires little to no consumables making the cost-per-test minimal.

 

 

 


Highlights

The InfraCal 2 Model ATR-SP & TRANS-SP can be ordered with various factory calibrations. They are available with a single or multiple calibrations. Calibration of the analyzer enables it to directly display oil/grease concentration levels in parts per million (ppm) or milligram/kg.

 

Instrument Type

Model InfraCal 2 TRANS-SP

Analytical Wavelength/Wave Number

3.4 µm, 2930 cm-1

Power Requirements

18 volts DC, 3.3 amps, internal battery pack available

Power Supply

Universal AC/DC provided

Weight

5.8 lb. (2.6 kg) with battery -7.0 lbs (3.2 kg)

Dimensions

(17 cm) x 7.8" (19.8 cm) x 5.2" (13.2 cm)

Suggested Operating Range

40°F (5°C) – 110°F (40°C)

Measurement Range

 

For Water

0.1-1000+ ppm

For Soil

1-5000+ ppm

Analysis Time

10-15 minutes, including extraction process

Instrument Repeatability

±0.1 ppm

Communication Port

USB, RS 232

 
Tampilkan Lebih Banyak

ANDALAN PRIMA SEJAHTERA

Kami CV ANDALAN PRIMA SEJAHTERA.

Alamat

Jl. Muchtar Tabrani, Bintang Metropol Blok A-7 No. 16 , Bekasi Utara

Phone    : 021 - 29253187, 29253184,  Fax : 021-29253186

Email     : support@andalanprimasejahtera.com / maria@andalanprimasejahtera.com

Website : www.andalanprimasejahtera.com

 

Yang berdiri sejak tahun 2005 adalah  distributor laboratory equipment, reagent, measuring  and test instrument

 

Perusahaan kami mengageni beberapa produk yaitu, peralatan untuk oil dan gas, lingkungan , Electrical, Kimia dan air

 

Perlu kami sampaikan pula bahwa kami mempunyai tenaga yang profesional dalam menangani pemasangan dan perbaikan alat/barang untuk keperluan laboratorium dan menjamin After Sales Service bagi barang atau peralatan yang kami supplay.

Tampilkan Lebih Banyak

ANDALAN PRIMA SEJAHTERA

Free Member
 
Jl. Muchtar Tabrani Perum. Bintang Metropol Blok A7 no 16
Jawa Barat - Bekasi
Login Terakhir 12-02-2019
02129253184
081290773137

Produk Lainnya


CALL
Alat Uji Lingkungan
CALL
Alat Uji Lingkungan
CALL
Alat Uji Lingkungan
CALL
Alat Uji Lingkungan
CALL
Alat Uji Lingkungan
CALL
Alat Uji Lingkungan