Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)
| DC Current | 600.0 A/2000 A, Basic accuracy: ±1.3% rdg. ±3 dgt. |
|---|---|
| AC Current | 600.0 A/2000 A (10 Hz to 1 kHz, True RMS), Basic accuracy: ±1.3% rdg. ±3 dgt. |
| DC Voltage | 600.0 mV to 1500 V, 5 ranges, Basic accuracy: ±0.5% rdg. ±3 dgt. |
| AC Voltage | 6.000 V to 1000 V, 4 ranges (15 Hz to 1 kHz, True RMS), Basic accuracy: ±0.9% rdg. ±3 dgt. |
| DC+AC Current | 600.0 A/2000 A (10 Hz to 1 kHz, True RMS), Basic accuracy: ±1.3% rdg. ±13 dgt. |
| DC+AC Voltage | 6.000 V to 1000 V, 4 ranges, Basic accuracy: ±1.0% rdg. ±7 dgt. |
| Resistance | 600.0 Ω to 600.0 kΩ, 4 ranges, Basic accuracy: ±0.7% rdg. ±5 dgt. |
| Electrostatic capacity | 1.000 μF to 1000 μF, 4 ranges, Basic accuracy: ±1.9% rdg. ±5 dgt. |
| Frequency | 9.999 Hz to 999.9 Hz, Basic accuracy: ±0.1% rdg. ±1 dgt. |
| Continuity check | Continuity threshold [ON]: 25Ω±10 Ω (Buzzor sound, red LED), Continuity threshold [OFF]: 245 Ω±10 Ω, Response time: 0.5 ms or more |
| Diode | Open terminal voltage: DC2.0 V or less, Short-circuit current: 200 μA, forward connection: 0.15 V to 1.8 V |
| Temperature (K) | -40.0 to 400.0 ˚C, add temperature probe accuracy to basic accuracy of ±0.5% rdg. ±3.0 ˚C |
| Voltage detection | Hi: 40 V to 600 V AC, Lo: 80 V to 600 V AC, 50/60 Hz |
| DC Power | Display range switching: 0.000 VA to 3400 kVA, Accuracy: ±2.0% rdg. ±20 dgt. |
| Crest factor | [600.0 A range] 500.0 A or less: 3; greater than 500.0 A and less than or equal to 600.0 A: 2.5 [2000 A range] 1000 A or less: 2.84; greater than 1000 A and less than or equal to 2000 A: 1.42 |
| Other functions | Automatic AC/DC detection, Plus/Minus judgement function of DC A, DC V, Max/Min/Average/PEAK MAX/ PEAK MIN value display, Filter function, Display value hold, Auto hold, Back light, Auto-power save, Buzzer sounds, Zero-adjustment |
| Dustproof, waterproof | Grip: IP54 (when measuring an insulated conductor only), Jaw (the current sensor portion of the instrument)/ barrier: IP50 *Risk of electric shock from the conductor being measured increases when wet. |
| Display | Update rate: 5 times/s (excluding electrostatic capacity, frequency, and temperature) |
| Power supply | LR03 Alkaline battery ×2, Continuous use 45 hr (Backlight OFF) |
| Core jaw diameter | 92 mm (3.62 in) W×18 mm (0.71 in) D, φ55 mm (2.17 in) |
| Dimensions and mass | 65 mm (2.56 in) W×250 mm (9.84 in) H×35 mm (1.38 in) D mm, 530 g (18.7 oz) |
| Accessories | TEST LEAD L9207-10, CARRYING CASE C0203, LR03 Alkaline battery ×2, Instruction Manual ×1 |
ANDALAN PRIMA SEJAHTERA
Kami CV ANDALAN PRIMA SEJAHTERA.
Alamat
Jl. Muchtar Tabrani, Bintang Metropol Blok A-7 No. 16 , Bekasi Utara
Phone : 021 - 29253187, 29253184, Fax : 021-29253186
Email : support@andalanprimasejahtera.com / maria@andalanprimasejahtera.com
Website : www.andalanprimasejahtera.com
Yang berdiri sejak tahun 2005 adalah distributor laboratory equipment, reagent, measuring and test instrument
Perusahaan kami mengageni beberapa produk yaitu, peralatan untuk oil dan gas, lingkungan , Electrical, Kimia dan air
Perlu kami sampaikan pula bahwa kami mempunyai tenaga yang profesional dalam menangani pemasangan dan perbaikan alat/barang untuk keperluan laboratorium dan menjamin After Sales Service bagi barang atau peralatan yang kami supplay.
Produk Lainnya
BAGSMART Tote Bag Expandable 28L Duf
Rp. 381.000
Alat Pemotong Kentang Spiral Stainle
Rp. 153.000
iPhone 12 64GB/128GB/256GB BEKAS SEC
Rp. 3.950.000
Kopi Celup Arabika Gayo Aceh Asli Mu
Rp. 9.000
Leedoo Sepatu Sekolah Sepatu Sneaker
Rp. 127.500